MAGNETIC CONTATACTOR & SWITCH
Rating
Type |
DM9C |
DM12C |
DM18C |
DM22C |
Rating
KS C
4504 |
3-phase Squirrel Cage Motor |
AC3 Class |
200-220V |
2.2kW 11A
|
2.7kW 13A |
3.7kW 18A |
4kW 20A |
380-440V |
2.7kW 7A |
4kW 9A
|
5.5kW 13A |
7.5kW 20A |
500-550V |
2.7kW 6A |
5.5kW 9A |
5.5kW 13A |
7.5kW 17A |
AC4 Class |
200-220V |
1.5kW 8A |
2.2kW 11A |
3.7kW 18A
|
3.7kW 18A |
380-440V |
2.2kW 6A |
4kW 9A |
4kW 9A
|
5.5kW 13A |
Single Phase Motor |
110V |
0.4kW 11A |
0.5kW 13A |
0.75kW 18A
|
0.9kW 20A |
220V |
0.8kW 11A |
1kW 13A |
1.5kW 18A
|
1.8kW 20A |
Resistance Load
(DC1 Class) |
2-pole Series |
110V |
6A |
10A |
13A
|
15A |
220V |
3A |
7A |
8A
|
12A |
3-pole Series |
110V |
8A |
12A |
18A
|
20A |
220V |
8A |
12A |
18A
|
20A |
Life (10 thousand times) |
Electrical |
250 |
250 |
250
|
250 |
Mechanical |
2500 |
2500 |
2500
|
2500 |
Auxiliary Contact(Standard) |
1a1b |
1a1b |
1a1b
|
1a1b |
Auxiliary Contact |
Side Attachment(Side-on) |
DAU2Sb |
DAU2Sb |
DAU2Sb
|
DAU2Sb |
Head-on |
DAU2C, DAU4C |
DAU2C, DAU4C |
DAU2C, DAU4C |
DAU2C, DAU4C |
Installation Method |
Screw, DIN rail combined use |
External Size(mm) (Width X Height X Height) |
44 X 80.7 X 86.7 |
44 X 80.8 X 86.7 |
Installation size(mm) (Width X Height) |
31~36 X 49~65, 35 X 65 |
Application Model |
Contactor |
Reversible |
DM9C-R
|
DM12C-R |
DMC18C-R |
DM22C-R |
Switch |
Standard |
DMS9C |
DMS12C
|
DMS18C |
DMS22C |
Reversible |
DMS90-R |
DMS12C-R |
DMS18C-R |
DMS22C-R |
Entry type (Steel) |
DMW9C |
DMW12C |
DMW18C
|
DMW22C |
Thermal Overload Relay |
Standard |
DTH22b |
DTH22b |
Single Attachment Type |
DTZ22b |
DTZ22b |
|
Download PDF Download DWG |
Download PDF Download DWG |
Download PDF Download DWG |
Download PDF Download DWG |
Type |
DM32C |
DM40C |
DM48C |
Rating
KS C
4504 |
3-phase Squirrel Cage Motor |
AC3 Class |
200-220V |
5.5kW 26A |
7.5kW 35A
|
11kW 48A |
380-440V |
11kW 25A |
15kW 32A |
15kW 32A |
500-550V |
11kW 20A |
15kW 26A |
15kW 26A |
AC4 Class |
200-220V |
4.5kW 20A |
5.5kW 25A |
7.5kW 35A |
380-440V |
7.5kW 17A |
11kW 24A |
15kW 32A |
Single Phase Motor |
110V |
1.2kW 26A |
1.7kW 35A |
- |
220V |
- |
- |
- |
Resistance Load
(DC1 Class) |
2-pole Series |
110V |
25A
|
25A
|
35A |
220V |
12A
|
12A
|
15A |
3-pole Series |
110V |
25A
|
35A
|
50A |
220V |
22A
|
30A
|
45A |
Life (10 thousand times) |
Electrical |
200 |
200 |
200 |
Mechanical |
1500 |
1500 |
1500 |
Auxiliary Contact(Standard) |
2a2b |
2a2b |
2a2b |
Auxiliary Contact |
Side Attachment(Side-on) |
DAU2Sb |
DAU2Sb |
DAU2Sb |
Head-on |
DDAU2C, DAU4C |
DDAU2C, DAU4C |
DDAU2C, DAU4C |
Installation Method |
Screw, DIN rail combined use |
External Size(mm) (Width X Height X Height) |
66 X 85.5 X 94.5 |
Installation size(mm) (Width X Height) |
35 X 60, 35 X 75 |
Application Model |
Contactor |
Reversible |
DW32C-R |
DM40C-R |
DM48C-R |
Switch |
Standard |
DMS32C |
DMS40C |
DMS48C |
Reversible |
DMS32C-R |
DMS40C-R |
DMS48C-R |
Entry type (Steel) |
DMW32C |
DMW40C |
DMW48C |
Thermal Overload Relay |
Standard |
DTH40 |
Single Attachment Type |
DTZ40b |
|
Download PDF Download DWG |
Download PDF Download DWG |
Download PDF Download DWG |
Type |
DM50C |
DM65C |
DM75C |
Rating
KS C
4504 |
3-phase Squirrel Cage Motor |
AC3 Class |
200-220V |
11kW 50A |
15kW 65A
|
18.5kW 75A |
380-440V |
22kW 48A
|
30kW 65A
|
37kW 75A |
500-550V |
22kW 38A
|
37kW 60A
|
37kW 64A |
AC4 Class |
200-220V |
7.5kW 35A
|
11kW 50A
|
13kW 55A |
380-440V |
15kW 32A
|
22kW 47A
|
25kW 52A |
Single Phase Motor |
110V |
-
|
-
|
- |
220V |
-
|
-
|
- |
Resistance Load
(DC1 Class) |
2-pole Series |
110V |
35A
|
35A
|
50A |
220V |
15A
|
15A
|
20A |
3-pole Series |
110V |
50A
|
65A
|
70A |
220V |
40A
|
50A
|
55A |
Life (10 thousand times) |
Electrical |
200
|
200
|
200 |
Mechanical |
1000
|
1000
|
1000 |
Auxiliary Contact(Standard) |
2a2b
|
2a2b
|
2a2b |
Auxiliary Contact |
Side Attachment(Side-on) |
DAU2Sb
|
DAU2Sb |
DAU2Sb |
Head-on |
DAU-2C, DAU-4C |
DAU-2C, DAU-4C |
DAU-2C, DAU-4C |
Installation Method |
Screw, DIN rail combined use |
External Size(mm) (Width X Height X Height) |
79 X 109 X 119.5 |
Installation size(mm) (Width X Height) |
41~47 X 92~100 |
Application Model |
Contactor |
Reversible |
- |
- |
- |
Switch |
Standard |
- |
- |
- |
Reversible |
- |
- |
- |
Entry type (Steel) |
- |
- |
- |
Thermal Overload Relay |
Standard |
DTH85㈜1 |
Single Attachment Type |
- |
|
Download PDF Download DWG |
Download PDF Download DWG |
Download PDF Download DWG |
Type |
Rating DM85C |
Rating DM100C |
Rating
KS C
4504 |
3-phase Squirrel Cage Motor |
AC3 Class |
200-220V |
19kW 80A
|
25kW 100A |
380-440V |
37kW 80A |
50kW 100A |
500-550V |
45kW 75A |
55kW 80A |
AC4 Class |
200-220V |
15kW 65A |
19kW 80A |
380-440V |
30kW 62A |
37kW 75A |
Single Phase Motor |
110V |
- |
- |
220V |
- |
- |
Resistance Load
(DC1 Class) |
2-pole Series |
110V |
50A |
80A |
220V |
20A |
50A |
3-pole Series |
110V |
80 |
100A |
220V |
A60A |
80A |
Life (10 thousand times) |
Electrical |
200 |
100 |
Mechanical |
1000 |
500 |
Auxiliary Contact(Standard) |
2a2b |
2a2b |
Auxiliary Contact |
Side Attachment(Side-on) |
DAU2Sb |
DAU2Sb |
Head-on |
DAU-2C, DAU-4C |
DAU-2C, DAU-4C |
Installation Method |
Screw, DIN rail combined use |
External Size(mm) (Width X Height X Height) |
94 X 140.5 X 134.4 |
Installation size(mm) (Width X Height) |
55~60 X 130 |
Application Model |
Contactor |
Reversible |
- |
- |
Switch |
Standard |
- |
- |
Reversible |
- |
- |
Entry type (Steel) |
- |
- |
Thermal Overload Relay |
Standard |
DTH85㈜1 |
Single Attachment Type |
- |
|
Download PDF Download DWG |
Download PDF Download DWG |